Specification
|
Item No. |
Output torque |
Rate speed |
Maximum number of output shaft revolutions |
Maximum weight of the door leaf. |
Voltage |
Power |
Gearbox Ratio |
Protection class |
Maximum time of continuous operation |
|
IN-I |
35N.m |
31RPM |
17revolutiongs |
180KG |
AC110V-AC220V/50Hz-60Hz |
750W |
48:1 |
IP65 |
10 min |
|
IN-II |
50N.m |
24RPM |
17revolutiongs |
260KG |
AC110V-AC220V/50Hz-60Hz |
670W |
58:1 |
IP65 |
10 min |
|
IN-III |
50N.m |
24RPM |
17revolutiongs |
260KG |
AC110V-AC220V/50Hz-60Hz |
610W |
58:1 |
IP65 |
15 min |
|
IN-IV |
100N.m |
24RPM |
17revolutiongs |
500KG |
AC380V/50Hz |
1000W |
58:1 |
IP65 |
15 min |
|
IN-V |
130N.m |
18RPM |
17revolutiongs |
650KG |
AC380V/50Hz |
1000W |
80:1 |
IP65 |
15 min |
Features
- This door opener is used in large warehouses or labor industries.
- Precise adjustment is possible thanks to an advanced restricted switch design.
- Lower noise, higher IP class.
- It's easy to install. In the event of a power outage, the gate can be manually opened and closed after the clutch is released.
- The door opener has an overheat protection feature.
- Better grease and a door-opening machine that requires no maintenance.
Advantages
To accommodate varying voltages, a variety of models can be chosen.
There are differences in the maximum weight that can be carried.
High level of protection, resistant to harm, and able to adjust to various pressure levels.
The new look is more stunning and atmospheric than the old.
Tips For Industrial Door Opener Maintenance And Upkeep
Frequent cleaning
Cleaning appearance: Regularly clean the industrial door opener's exterior to get rid of dust and grime. You can wipe it with a gentle, clean cloth. You can use a mild detergent to remove some stubborn stains. To prevent harming the door opener's housing, stay away from using strong acids, strong alkalis, or detergents with corrosive elements. Strong acids or alkalis, for instance, may corrode the metal surface of certain door openers with metal shells, reducing their longevity and aesthetic appeal. When cleaning, be sure to thoroughly clean every component of the door opener, such as the control box housing, motor housing, and transmission component housing.
Internal cleaning: When the equipment is having a thorough refurbishment, for example, clean the door opener's interior. First, turn off the power source, open the door opener's casing (if it can open on its own), and dust the inside with a hair dryer or a tiny vacuum. Special electronic cleaners can be used to clean electronic components, like inside circuit boards, but take care not to get the cleaner in contact with delicate areas like the component pins. At the same time, see if any detritus, like pebbles or pieces of paper, has accumulated inside. These debris may affect the normal operation of the door opener and should be cleaned up in time.
Maintenance and lubrication
Lubrication of transmission components: To lessen wear and increase transmission efficiency, the industrial door opener's transmission parts - such as chains, gears, pulleys, etc. Need to be greased on a regular basis. You can use a specific chain lubricant for chain transmission and apply the right amount to each chain link on a regular basis (every one to three months, depending on how often you use it). Clean the chain's surface of any dirt before lubricating it. To guarantee that the meshing surface of the gear is completely lubricated, gear oil can be used to lubricate the gears of the gear drive. If a rubber belt is being used for pulleys, use a lubricant that is appropriate for rubber and steer clear of lubricants with excessive oil to prevent the belt from corroding.
Lubrication of the motor (if required): Depending on the kind and construction of the motor, some industrial door openers may require routine lubrication. If a motor has bearings, make sure the bearings are lubricated on a regular basis. The bearing can be oiled with an appropriate bearing lubricant if it is discovered to be dry or to be making unusual noises. To prevent short circuits and other issues, lubricate the motor according to its recommendations to prevent lubricating oil from getting into the motor windings and other components.
Examining And Tightening
Inspection of components: Check the industrial door opener's motor, gearbox parts, sensors, control box, and other parts on a regular basis. Examine the motor for any unusual noise, vibration, or warmth, as these could be signs of impending motor failure. For the gearbox parts, look for signs of wear on the gear tooth surface, cracks or aging in the belt, and loose, worn, or broken chain. Verify the sensor's ability to sense normally by checking for things like signal interference in the microwave sensor and the infrared sensor's sensing distance. Examine the control box's electrical components for burns or loose parts.
Hot Tags: industrial gate operators, China industrial gate operators manufacturers, suppliers, factory, Automatic Sliding Gate Opening System, Smart Sliding Gate Opener, sliding gate opener, Swing Arm Gate Operators, Door Opener Steel Gear Rack, Remote Control Sliding Gate Motor