Specification
|
Item No. |
Voltage |
Power |
Gate width |
Opening time |
Limit switch |
Noise |
Temperature |
Protection class |
Certification |
|
ARM-3D |
AC120V/AC230V |
150W |
3m |
19s |
Mechanical limited switch (NC/NO) |
≤56dB |
-45℃-+65℃ |
IP44 |
CCC, CE |
|
ARM-5D |
AC120V/AC230V |
150W |
5m |
32s |
Mechanical limited switch (NC/NO) |
≤56dB |
-45℃-+65℃ |
IP44 |
CCC, CE |
|
ARM-3D-BL |
DC24V |
100W |
3m |
10s |
Mechanical limited switch (NC/NO) |
≤56dB |
-45℃-+65℃ |
IP44 |
CCC, CE |
|
ARM-5D-BL |
DC24V |
100W |
5m |
10s |
Mechanical limited switch (NC/NO) |
≤56dB |
-45℃-+65℃ |
IP44 |
CCC, CE |
Features
- Drived by thread pole.
- Mechanical limit switch.
- Outside control box.
- Can chose one or two gates to open or close.
- Brussless motor could be chosen.
- In case of power failure, the gate can be opened and closed manually after releasing clutch.
Advantages
- Exclusive R&D team, independent research and development, novel shape, simple atmosphere, strong sense of streamline.
- The surface of the motor is smooth, the whole is strong, anti-collision and anti-fall.
- Can be applied to 3 meters and 5 meters distance of the door, also suitable for a variety of materials, such as wrought iron doors, copper doors, stainless steel doors, wooden doors.
- High strength screw drive, strong and durable.
- Stiffened tail frame for higher durability.
- Overseas sales rate is high, and sales are increasing year by year.
Product Application Scenario:
Factories, hotels, parking lots, communities, schools, private houses, office buildings, etc.
Production Process:
Die casting, spray, injection molding, metalworking, assembly, testing, quality inspection.
Typical Swing Door Opener Issues And Fixes
The motor is not starting
Absence of power
It's possible that the power supply has failed if the electric remote control swing door motor is powered but won't start. Initially, examine the plug and power line for damage, as well as any broken or damaged wires and whether the plug is securely plugged in. over instance, the internal wire may break if the power cord is crushed by the door body over an extended period of time. Check to see if the power switch is on at the same moment. The power switch may occasionally malfunction and turn off. Another option is to try replacing or repairing the power line. You can check to see if the power supply voltage is normal with an electric meter if you think it might be abnormal. You must promptly replace the power supply if the voltage value is abnormal. For instance, the typical voltage for a 220V motor should be between 198 and 242V, or within ±10% of the specified voltage.
Failure of the motor
It's possible that the motor itself is malfunctioning if the power supply is normal yet the motor still won't start. First, see if the motor has any issues, such loose circuits, and see if there are any loose wires at the motor terminals that could be blocking the circuit. If everything is in order, you can check if the motor's voltage and current are normal using an electric meter. The motor's winding or other internal parts may be malfunctioning if the voltage and current are within normal limits.In this instance, a professional is required to replace or repair the motor. For instance, prolonged running may cause the motor's stator winding to overheat and burn, or the motor's rotor to become stuck by foreign objects and lose its ability to revolve.
Failure of the controller
The failure of the sliding door controller is likely to result in the motor not starting, in addition to issues with the power supply and the motor itself. Verify the controller's indicator light, control circuit, switch position, etc. If the controller's indicator light is off, it could mean that the power circuit inside the controller is broken or that the controller is not receiving power. Verify if the control circuit is broken, loose, or shorted out. For instance, when the door body moves often, the control circuit might be tugged, disconnecting the circuit. In the event that an anomaly is discovered, the controller must be promptly changed or fixed, such as by changing the internal circuit board or fixing the control circuit's connecting point.
Other explanations
If the sliding door motor still won't start after resolving the first three issues, there might be more issues at play. For instance, the signal transmission between the controller and the remote control can be problematic. The remote control appears to be operating normally, but the controller is unable to receive the signal properly. Alternatively, the motor may not be able to move the door due to a mechanical issue with the door itself, such as a jammed door or a deformed guide rail.To get expert technical support and troubleshooting solutions in this situation, you can attempt contacting the manufacturer or after-sales service staff. To determine what caused the failure, they might employ specialized testing apparatus.